Ideal for protecting: Critical Networks
Manageability
- The graphical LCD display provides clear information on the UPS's status and measurements on a single screen. Enhanced configuration capabilities are also available.
- 9PX can meter energy consumption right down to the managed outlet groups. kWh values can be monitored using the LCD or Eaton's Intelligent PowerTM Software.
- Load segment control enables prioritised shutdowns of non-essential equipment to maximise battery runtime for critical devices.
- 9PX offers Serial and USB connectivity, plus an extra slot for an optional communication card. Eaton's Intelligent Power.
- Software seamlessly integrates with leading virtualisation environments and cloud orchestrations tools.
Availability and Flexibility
- 9PX 2200 & 3000 are available in RT2U format (optimised for rack mounting) or RT3U (for tower or shot-depth racks), pedestal and rail kits are included with all models.
- The internal bypass allows service continuity in case of internal fault, a maintenance bypass is also available (as standard on Hot Swap version) for easy replacement of the UPS.
- Stronger, longer battery life: Eaton ABM battery management technology uses an innovative three stage charging technique that extends battery life by up to 50%.
- More runtime can be added with up to 4 external hot swappable battery modules, able to run systems for hours if necessary.
Rating
Rating (VA/W) | 11kVA / 10kW |
Electrical Characteristics
Technology | Online Double Conversion with Power Factor Correction (PFC) System |
Nominal Voltage | 200 / 208 / 220 / 230 / 240 / 250V |
Input Voltage Range | 176 - 276V |
Output Voltage/THDU | 200 / 208 / 220 / 230 / 240 / 250V +/- 1%, THDU <2% |
Input Frequency Range/THDI | 40 - 70Hz, 50/60HZ auto selection, frequency converter as standard, THDI <5% |
Efficiency | Up to 95% in Online mode, 98% in High Efficiency Mode |
Crest Factor / Short Circuit Current | 3:1 / 150A |
Overload Capacity | 102-110%: 120s, 110-125%: 60s, 125-150%: 10s, >150%: 900ms |
Battery Runtimes (minutes)
Typical Backup Times at 50% Load | 13 |
Typical Backup Times at 70% Load | 9 |
Typical Backup Time with 1 EBM at 50% Load | 32 |
Typical Backup Time with 1 EBM at 70% Load | 21 |
Battery Management | ABM and temperature compensated charging method (user selectable), automatic battery test, deep discharge protection, automatic recognition of external battery units. |
Communication
Communication Ports | 1 USB port, 1 RS232 serial port (USB and RS232 ports cannot be used simultaneously), 4 dry contacts (DB9) |
Communication Slot | 1 slot for Network Card-MS (including in Netpack versions), ModBus-MS or Relay-MS cards |
Physical
Height | 44.0 cm |
Width | 26.0 cm |
Depth | 70.0 cm |
Weight | 86 kg |